There was a problem hiding this comment.
In the end, we decided to only include "CO2" in the "CO2 production" column. Therefore, there's no need to split out LULUCF in these queries and later sum them again in the query that is used in the chart.
There was a problem hiding this comment.
Personal preferences:
- I would create individual queries for 1) the energy nodes fossil CO2 capture and 2) the molecule nodes CO2 capture. This is because they require a different querying method (
direct_co2_output_production_capture_fossilvsdirect_reporting_emissions_co2_capture), which looks a bit more clear to me when queried in separate queries and then summed in one query. - I would subtract CO2 capture from direct air capture and LULUCF from the total by using the queries that you created for these, instead of the
EXCLUDE()function. This is preferred in terms of chart logic and keeping queries as generic as possible: you're creating the individual queries for this new chart, so when exceptions or exclusions have to be done in other queries for this chart, it's good to reuse them again these queries again. - Minor note: we never use
ML()in our queries. I'm not sure if this is a legacy attribute or if it's still validated well in the engine. I would avoid using this for now.
There was a problem hiding this comment.
In general for the capture-related queries: I would only just apply the NEG() function in the queries that are in the chart folder, and not in the queries that are in the general folder. The reason that we want to apply the NEG() is to show the values as negative in the dedicated chart, therefore it's more appropriate to use NEG() in the chart queries.
There was a problem hiding this comment.
Since in the mechanical turk test we want to check if the chart results are correct, I would use the chart queries instead of the queries from the general folder (the result will in this case not be different though).
b7ae089 to
a58bc02
Compare
a58bc02 to
3feef81
Compare
Context
A chart that displays the contribution of CO₂ capture to direct net emissions should be added to the ETM. The columns are in agreement with the data export of direct emissions: CO2 production, CO2 capture, Other GHG emissions and Total GHG emissions. In addition, captured CO₂ is broken down by technology.
Implemented changes
direct_emissions_co2_net_total, which is gross CO2 production minus all captured CO2.direct_emissions_bruto_netto_chart, referring to the queries above.Related
Goes with pull requests:
Checklist